{"title":"Mettler-Toledo Thornton","description":"\u003cp\u003eIndustrial surplus Mettler-Toledo Thornton parts and equipment, in stock at MRO Exchange.\u003c\/p\u003e","products":[{"product_id":"mettler-toledo-thornton-toc-analyzer-5000toc-pn-58-036-001-0326-1141","title":"Mettler-Toledo Thornton 5000TOC \/ 58 036 001 TOC Sensor","description":"\u003cp\u003eUsed in pharmaceutical, semiconductor, and ultrapure water monitoring applications, the Mettler-Toledo Thornton 5000TOC is an online total organic carbon sensor designed for continuous, real-time detection of organic contamination in process water systems. The sensor employs UV oxidation combined with differential conductivity measurement to determine TOC concentration, operating without moving parts for reduced maintenance requirements. Input power is 100 to 130VAC at 50 to 60Hz, rated at 25W. Fuse rating is 250V 1.25A 5x20mm, Type T time lag. Maximum sample inlet pressure is 85 PSIG. The unit includes a UV lamp replacement access cover, flow control adjustment, sample inlet, and sample outlet connections on the housing. A multi-pin 770MAX connection port is present for integration with the Thornton 770MAX multiparameter analyzer transmitter. The unit carries CE marking and UL Listing as measuring equipment (26MR). Part number is 58 036 001. Serial number is 508040025. Manufactured in the USA. A calibration sticker visible on the front panel indicates the unit was last calibrated in September 2020 with a due date of November 2021. The 5000TOC is a phased-out predecessor to the Mettler-Toledo Thornton 5000TOCi and meets USP and EP pharmacopeia instrumentation requirements. Buyers should verify current calibration status prior to use in regulated applications.\u003c\/p\u003e\n\n\u003cp\u003eStock # 0326-1141\u003c\/p\u003e","brand":"Mettler-Toledo Thornton","offers":[{"title":"Default Title","offer_id":49007923822832,"sku":"m01141","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/6648\/7280\/files\/4831DB35-3084-448B-85F9-7052F1A2DEB2.png?v=1784825050"},{"product_id":"mettler-toledo-thornton-toc-analyzer-5000toc-pn-58-036-001-0326-1142","title":"Mettler-Toledo Thornton 5000TOC \/ 58 036 001 TOC Sensor","description":"\u003cp\u003eUsed in pharmaceutical, semiconductor, and ultrapure water monitoring applications, the Mettler-Toledo Thornton 5000TOC is an online total organic carbon sensor designed for continuous, real-time detection of organic contamination in process water systems. The sensor employs UV oxidation combined with differential conductivity measurement to determine TOC concentration, operating without moving parts for reduced maintenance requirements. Input power is 100 to 130VAC at 50 to 60Hz, rated at 25W. Fuse rating is 250V 1.25A 5x20mm, Type T time lag. Maximum sample inlet pressure is 85 PSIG. The unit includes a UV lamp replacement access cover, flow control adjustment, sample inlet, and sample outlet connections on the housing. A multi-pin 770MAX connection port is present for integration with the Thornton 770MAX multiparameter analyzer transmitter. The unit carries CE marking and UL Listing as measuring equipment (26MR). Part number is 58 036 001. Serial number is 508040025. Manufactured in the USA. A calibration sticker visible on the front panel indicates the unit was last calibrated in September 2020 with a due date of November 2021. The 5000TOC is a phased-out predecessor to the Mettler-Toledo Thornton 5000TOCi and meets USP and EP pharmacopeia instrumentation requirements. Buyers should verify current calibration status prior to use in regulated applications.\u003c\/p\u003e\n\n\u003cp\u003eStock # 0326-1142\u003c\/p\u003e","brand":"Mettler-Toledo Thornton","offers":[{"title":"Default Title","offer_id":49007933686000,"sku":"m01142","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/6648\/7280\/files\/38CCF30D-0DAC-4ACE-A43B-E9D6E267DE1F.png?v=1784825054"},{"product_id":"mettler-toledo-thornton-toc-analyzer-5000toc-pn-58-036-001-0326-1143","title":"Mettler-Toledo Thornton 5000TOC \/ 58 036 001 TOC Sensor","description":"\u003cp\u003eUsed in pharmaceutical water systems and semiconductor ultrapure water monitoring, the Mettler-Toledo Thornton 5000TOC is an online Total Organic Carbon analyzer that uses UV oxidation combined with differential conductivity to continuously measure TOC concentrations in process water. Part number 58 036 001, serial number 508040018, manufactured in the USA.\u003c\/p\u003e\n\n\u003cp\u003eInput power is 100 to 130VAC, 50 to 60Hz, 25W. Fuse rating is 250V, 1.25A, 5x20mm, Type T (Time Lag). The unit carries UL US Listed and CE marks and is designated Measuring Equipment class 26MR. Maximum inlet sample pressure is 85 PSIG. Sample inlet includes a 60-micron inlet filter. The front panel includes status indicators for Fault, Error, Sensor Status, and UV Lamp ON, along with a UV lamp power switch. The rear panel provides an AC power connection port and a 770MAX connection via a multi-pin circular connector. A UV lamp replacement cover with quarter-turn fastener is accessible from the front. Both sample outlet and sample inlet fittings are present on the rear panel.\u003c\/p\u003e\n\n\u003cp\u003eThe 5000TOC is designed for connection to the Thornton 770MAX Multiparameter Analyzer Transmitter. Up to two 5000TOC sensors can operate simultaneously on a single 770MAX platform. The unit meets USP and EP 2.2.44 pharmacopeial requirements for TOC instrumentation. No moving parts are present in the measurement flow path. The item bears a vendor calibration label; calibration currency requires independent verification by the buyer.\u003c\/p\u003e\n\n\u003cp\u003eStock # 0326-1143\u003c\/p\u003e","brand":"Mettler-Toledo Thornton","offers":[{"title":"Default Title","offer_id":49007941517552,"sku":"m01143","price":1999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/6648\/7280\/files\/FC0F9A20-7067-4CDF-A18B-E2543AA2B5EB.png?v=1784825280"},{"product_id":"mettler-toledo-thornton-toc-analyzer-5000toc-5000toce-pn-58-036-001-0326-1145","title":"Mettler-Toledo Thornton 5000TOC \/ 5000TOCe \/ 58 036 001 TOC Sensor","description":"\u003cp\u003eThe Mettler-Toledo Thornton 5000TOCe is an online Total Organic Carbon sensor designed for continuous, real-time TOC monitoring in pure and ultrapure water systems. Part number 58 036 001, serial number 508040036, this unit is manufactured in the USA and carries UL listing and CE marking for Measuring Equipment (designation 26MR).\u003c\/p\u003e\n\n\u003cp\u003eInput power is 100 to 130 VAC at 50 to 60 Hz, drawing 25W. The fuse rating is 250V, 1.25A, 5x20mm, Type T (Time Lag). Maximum sample inlet pressure is 85 PSIG. The unit features a sample inlet and sample outlet port, a flow control knob, and a UV lamp replacement cover with a threaded access cap. Rear connectivity includes an AC power input and a 770MAX connection port via a multi-pin circular connector, allowing integration with Mettler-Toledo Thornton 770MAX multiparameter transmitters.\u003c\/p\u003e\n\n\u003cp\u003eThe front panel displays Fault, Error, Sensor Status, and UV Lamp ON indicators alongside a power button. The 5000TOCe designation represents the enhanced platform of the 5000TOC series, which uses UV oxidation combined with differential conductivity to quantify TOC concentration in process water. This instrument is commonly used in pharmaceutical water systems, semiconductor ultrapure water applications, and similar industries requiring compliance with USP and EP pharmacopeia TOC requirements. The 5000TOC platform is now phased out by Mettler-Toledo and has been succeeded by the 5000TOCi series with ISM capability.\u003c\/p\u003e\n\n\u003cp\u003eStock # 0326-1145\u003c\/p\u003e","brand":"Mettler-Toledo Thornton","offers":[{"title":"Default Title","offer_id":49007945122032,"sku":"m01145","price":1999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/6648\/7280\/files\/035A45D1-B3EE-4268-8261-F030F0C2DC44.png?v=1784825296"},{"product_id":"mettler-toledo-thornton-toc-analyzer-5000toci-pn-58036031-sn-817350523-0326-1146","title":"Mettler-Toledo Thornton 5000TOCi \/ 58036031 TOC Analyzer","description":"\u003cp\u003eUsed in pharmaceutical water systems, semiconductor ultrapure water monitoring, and power generation applications, the Mettler-Toledo Thornton 5000TOCi is an online Total Organic Carbon analyzer sensor that uses UV oxidation combined with differential conductivity measurement to continuously determine TOC concentrations in high-purity water. This unit carries part number 58036031 and serial number 817350523, manufactured in the USA.\u003c\/p\u003e\n\n\u003cp\u003eInput power is 100 to 130VAC at 50 to 60Hz, rated at 25W. Fuse type is T (time lag), rated 250V 1.25A, 5x20mm format. The enclosure features mounting flanges, a UV lamp replacement cover accessible from the side panel, an AC power entry connector, and a multi-pin transmitter connection port. A sample inlet and sample outlet with drain-before-shipping notation are present on the lower panel. Maximum sample inlet pressure is 85 PSIG. The unit is CE marked and UL listed as Measuring Equipment.\u003c\/p\u003e\n\n\u003cp\u003eThe 5000TOCi integrates Intelligent Sensor Management (ISM) diagnostics, which support predictive maintenance and sensor health monitoring. This model meets pharmaceutical compliance requirements including USP and EP 2.2.44, as well as ChP and JP pharmacopeial standards. Mettler-Toledo notes the 5000TOCi as a phased-out product. The unit is designed for use with the Thornton M800 multi-parameter transmitter, which is not included with this listing. A \"Unit Under Test\" label is affixed to the front panel.\u003c\/p\u003e\n\n\u003cp\u003eStock # 0326-1146\u003c\/p\u003e","brand":"Mettler-Toledo Thornton","offers":[{"title":"Default Title","offer_id":49007949840624,"sku":"m01146","price":2329.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/6648\/7280\/files\/D3F9C015-0215-458B-99B0-407F2C1D8903.png?v=1784825546"},{"product_id":"mettler-toledo-thornton-toc-analyzer-5000toc-pn-58-036-001-0326-1152","title":"Mettler-Toledo Thornton 5000TOC \/ 58 036 001 TOC Sensor","description":"\u003cp\u003eUsed in pharmaceutical and semiconductor ultrapure water monitoring applications, the Mettler-Toledo Thornton 5000TOC is an online total organic carbon analyzer based on UV oxidation with differential conductivity measurement. Manufactured in the USA, this unit carries part number 58 036 001 and serial number 508040014. Input power is 100 to 130 VAC at 50 to 60 Hz, rated at 25W. The fuse is rated at 250V, 1.25A, size 5x20mm, Type T (Time Lag). Maximum inlet sample pressure is 85 PSIG. The enclosure includes a sample inlet port, sample outlet port, and a flow control valve accessible from the bottom panel. Front panel indicators include UV Lamp ON, Sensor Status, Error, and Fault LEDs with a power toggle switch. The unit carries CE marking and is UL Listed under the Measuring Equipment category (26MR). The 5000TOC meets instrumentation performance criteria for TOC as defined in USP, European Pharmacopoeia, and Japanese Pharmacopoeia requirements. The sensor operates without moving parts, which reduces routine maintenance intervals. A yellow vendor calibration sticker is affixed to the front face. The 5000TOC is the predecessor generation to the 5000TOCe and 5000TOCi platform. No display, transmitter, or controller is included with this unit.\u003c\/p\u003e\n\n\u003cp\u003eStock # 0326-1152\u003c\/p\u003e","brand":"Mettler-Toledo Thornton","offers":[{"title":"Default Title","offer_id":49008464232688,"sku":"m01152","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/6648\/7280\/files\/2802D9AD-ED36-449E-8B76-87B98E62C3B2.png?v=1784825997"},{"product_id":"mettler-toledo-thornton-toc-sensor-5000toc-pn-58-036-001-0326-1157","title":"Mettler-Toledo Thornton 5000TOC \/ 58 036 001 TOC Sensor","description":"\u003cp\u003eUsed in pharmaceutical water systems, semiconductor ultrapure water monitoring, and process water quality control, the Mettler-Toledo Thornton 5000TOC is an online total organic carbon sensor designed for continuous, real-time TOC measurement. The 5000TOC uses UV oxidation combined with differential conductivity detection to determine organic carbon concentration across a wide dynamic range from sub-ppb to ppm levels. The unit carries part number 58 036 001 and serial number 508040022. Input power is 100 to 130VAC at 50 to 60Hz, 25W. The fuse rating is 250V, 1.25A, 5x20mm Type T (Time Lag). Maximum sample inlet pressure is 85 PSIG. Sample inlet and outlet connections are visible on the rear panel. The front panel includes indicators for UV Lamp On, Sensor Status, Error, and Fault, along with a power switch. The unit is compatible with the Mettler-Toledo Thornton 770MAX multiparameter transmitter. The instrument is UL listed (26MR) and CE marked. The product is made in the USA. A calibration status sticker is visible on the front panel; calibration status should be independently verified by the buyer. This unit is offered as surplus and has not been tested by the seller.\u003c\/p\u003e\n\n\u003cp\u003eStock # 0326-1157\u003c\/p\u003e","brand":"Mettler-Toledo Thornton","offers":[{"title":"Default Title","offer_id":49011889307888,"sku":"m01157","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/6648\/7280\/files\/E338D02C-C263-42BF-8808-AAC593D1949B.png?v=1784826160"},{"product_id":"mettler-toledo-thornton-toc-analyzer-5000toci-pn-58036031-005-to-2000-ppbc-0326-1164","title":"Mettler-Toledo Thornton 5000TOCi \/ 58036031 TOC Analyzer 0.05 to 2000 ppbC","description":"\u003cp\u003eUsed in pharmaceutical water systems, semiconductor ultrapure water monitoring, and high-purity water treatment applications, the Mettler Toledo Thornton 5000TOCi is an online Total Organic Carbon analyzer designed for continuous, real-time measurement of TOC concentrations. Part number 58036031, serial number 818180164. Manufactured in the USA and UL listed as measuring equipment (File 26MR).\u003c\/p\u003e\n\n\u003cp\u003eThe 5000TOCi uses UV oxidation combined with differential conductivity measurement to determine TOC levels across a range of 0.05 to 2000 ppbC (per published manufacturer specifications). Input power is 100 to 130VAC, 50 to 60Hz, 25W. Fuse rating is 250V, 1.25A, 5x20mm, Type T (time lag). The unit features status indicators for UV Lamp ON, Sensor Status, Error, and Fault on the front panel.\u003c\/p\u003e\n\n\u003cp\u003eThe instrument complies with global pharmacopeia standards including USP, EP, JP, ChP, and IP for TOC instrumentation, making it applicable to pharmaceutical manufacturing environments where regulatory compliance for water quality is required. No moving mechanical components are used in normal operation, which reduces routine maintenance requirements. The UV lamp and filter are serviceable wear components with a manufacturer-recommended replacement interval of 4,500 operating hours.\u003c\/p\u003e\n\n\u003cp\u003eThe front enclosure includes a hinged cover with triangular fasteners and a sample outlet fitting. The 5000TOCi is compatible with the Mettler Toledo M800 multi-parameter transmitter for integrated multi-sensor system configurations.\u003c\/p\u003e\n\n\u003cp\u003eStock # 0326-1164\u003c\/p\u003e","brand":"Mettler-Toledo Thornton","offers":[{"title":"Default Title","offer_id":49418213753072,"sku":"m01164","price":2499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/6648\/7280\/files\/6DC332FA-D312-4D00-B7F2-DD858486C0A3.png?v=1784826483"}],"url":"https:\/\/mroexchange.com\/collections\/mettler-toledo-thornton.oembed","provider":"MRO Exchange","version":"1.0","type":"link"}